All Rights Reserved. If from the top, try tightening the lid with a #3 Philips, or replace the lid o-ring. Hi Marshall, check that the water level is good, and skimmer weirs are not stuck, blocking water flow into the skimmer, both cases cause the skimmer to suck air, which cause the pump to lose prime. Maybe the transformer is not functioning properly? I assume assy A motor is just bad. We live in Arizona, so the automatic freeze setting isnt an issue. Please help! I have chalked all the connections and lubricated the basket seal. I would think that going to 1 hp superpump, from a 1.5 hp superpump, would not be a problem. For a better experience, please enable JavaScript in your browser before proceeding. I have removed and tested the capacitor it appears OK I then removed the thermostat to try to access the shaft and turn it with a 7/17 wrench, but the protrusions on the casting and other spring mounted stuff appear to make it impossible to get a grip on the shaft. If so, you can replace just the motor, or the entire pump. The main filters and baskets are well maintained. Hope thats not the case. Yesterday I plugged it in to filter and where the plug goes into the 3 foot heavy duty extension it sparked smoked and created a small flame. Are you getting 230V (207v 253V) at the pump? If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. My hayward powerflo matrix 1.5hp pump doesnt turn on after working fine the whole month of June. Hi Rachel, when there is no sound at all i would check the circuit breaker to be sure it is on. BTW, this can be caused from a water hammer effect, running the pump and then shutting off flow suddenly, or the fitting could have been overtightened to begin with, 7 years ago, and age caused it to give way. When it stops again, you may want to pull off the filter valve from the filter, and inspect the top few inches of sand, maybe replacing it with new. Hi. There is water, not a lot, but water at the base of the pump. This is our second season for this pump. A less common cause of water out of the waste line is a broken Spring, under the handle, indicated by a floppy handle or difficulty turning the valve, I have a Hayward Super Pump it will run for about 1 to 2 hours and then it shuts off once it cools off for an hour or so I can turn it back on it will run again the water flow its good its just shuts off when it gets hot, Hi Steve; check that you have good air flow all around the pump, and above. So if the water flow thru the unit is normal then I would next assume a bad flow switch or sensor (depending on what type of pool equipment we are talking about pump, salt cell, heater). I turned the gas off to it. Do I have a problem? However this is not correct operation. dhp faux leather club chair; hanna salinity tester calibration; Cant find anything that jumps right out. Ive read online it is most liked a valve that is faulty in some way. Hi thanks for speedy reply the breaker is 20 amp with a GFCI. If the impeller wont spin, this is likely the problem. I believe I have a bad capacitor. What is the problem with those other motors? Tried to backwash. I can see the water trickling in to the filter after a while, and the output becomes very limited. Remove the bracket and inspect for bulging, cracking, or burnt marks on the end. It may not display this or other websites correctly. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. However, when I check the connection at the wired, there is definetly juice there. Hi Chuong, the Leslies RS750CA is the same as the Hayward Super II pump, which are $500-$600. Third possibility is the pipe size is too small, and your 90 gpm pump may be starved for water. The outlet the pump is plugged into, I suppose that is a 240V outlet. However, many inground pools do not run the pump 24/7, but operate it from 12-18 hrs daily, depending on the need, and the ability of the filtration system and sanitation efforts, etc Some small systems do need to run 24/7, but a properly sized system has a timeclock, to set it to run for around 12 hours per day (less during cool periods, more during hot spells)>. Please help. After running almost 24 hours the pressure went upto 30 which is the maxium number on our filter gauge and the water circulation stopped. the pop may have been the capacitor blowing, its a black cylinder located at 9 oclock in the rear of the motor. If your salt cell is plugged into an GFI outlet, make sure that the test button is not popped, or tripped. You could use a small plug-in pump timer that would allow you to not unplug, just flip the switch to off. The breaker is still left on the on position any idea what it might be? The Filter Design Flow Rate is usually printed on the label, or can be found online. Check power at the switch or timer in the same way as the motor, at the other end of the wires running between the switch/timer and motor. Also, because of this leak, would It cause my pressure to decrease? It's the same as an aquarite with a T-5 cell. I doubt you damaged anything, or have any big issues, should be OK. The electrician also installed w new capacitors on the pump and still same problem. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. My pump seems to trip the GFCI breaker each time it is plugged in. hayward blue essence troubleshootingsolar panel for arlo essential spotlight camera hayward blue essence troubleshooting Menu everydrop water filter comparison. Set the test meter to Ohms, of 1K or higher. Thank you I have taken the thing apart several times and cleaned those fingers but that wasnt the problem this timeI took a chance and tried the vacuum to see if any debris actually made it to the filter basket and nothing went throughso got a plunger and forced the water through with that and then the pump finally primed!! Nick, it could be the capacitor, I guess water got on the terminal board, to trip the breaker. Good that you have the waterfall pump, that will help tremendously. When the pool guy switched it, it worked very well for about a month with no issues at all. The pump never turns off but it should pull the water through constantly. Hi, I just had an electrician install a Hayward Super II Energy Efficient Pump 3/4 HP SP3007EECA. Is there any other switch? Is this normal? To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. 5 Changed the seal I have a hayward superpump and upon starting the pump, it sucks the water into the pump basket but when it is filled with water the pump will start revving up and down. Because all the pipes are new and no leaks have been evident, I can say with confidence that #2 is not it. We have just replaced the seal assembly as suggested by a Hayward rep already. When it cools it automatically trys to start again and motor turns on after 3 seconds of humming. Hi Rob, If the pump is the same exact model and horsepower, it sounds like either; 1).
Hayward Blue Essense-20 | Trouble Free Pool Hi Jennifer, many Matrix pumps have an on/off switch on the rear bottom of the motor cap end. The previous owners winterized the pump and pool but left all the water in the pool so its full and nasty. died and I put in the old repaired motor. No loose wires or insect infestation. 1. If the blower prover switch opens during the postpurge cycle (heater is not firing) the control will display the error code. Either the pump lid oring is missing, or the lid (cover) is not tight, or a loose threaded pipe coming into the pump, or leaky valves (skimmer, main drain) air leaks are always in front of the pump. If you have found a burnt spot or something broken on the circuit board, that is a likely power killing area. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. Do they sometimes have to be replaced? Can I turn on this pump without water to check whether the motor is running? Any suggestions. Works great minus the vacuum created is so great that getting the lid off of the basket is so great a breaker bar is needed to remove it. 3 possible solutions. It could have also overheated, when this happens, it will work again after cooling down. thanks. Or you can try a filter cleaner first, to remove oils and scale that may be clogging the filter. You could provide a kind of tabletop shade to the motor, but dont enclose it and restrict air flow. Step 5: Measure your cells polarity to ensure they meet system parameters. Only thing I can think of, is the Key assy aligned properly when it was screwed back onto the valve body? The salt cylinder is clean. Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. They just reopened my pool. Could be the use of a clarifier or flocculent that is clogging the sand? Hi COnnie, great question! Also check the threaded pipe that comes into the pump, #1 most common air leak. Its a ecoclear 1.5hp. Below is the troubleshooting guide for Hayward pool heater error codes. Hi, it is either an air leak (a non-issue if installed below water level), or the suction pipes are too small for the pump size, or the hose may be collapsing inward under pressure. Third, could be clogging in the filter, or bad filter sand, if you have a sand filter. When I switch to waste or backwash, the suction is restored to full power and the flow is at full strength. Rust can develop inside the motor that you can break free, by spinning the shaft a few times. If you are getting correct voltage into the rear of the motor (120V or 240V, +/- 10%), but still the motor makes no noise at all, its likely DOA the motor at least. otherwise all else seems to read ok. Id check the cell number just to confirm it is the TCELL15. If none of those, it likely is an internal short across the wirings, or a bent shaft, which is the end of that motors life. News Reporter Reveals On Live TV That Shes Been Secretly Recording Dec 14, 2021. I have a Hayward pro max 1.5hp with sand filter but the suction into basket is not good. It can also be a bad outlet, and if older than 20 yrs, it could be the breaker too. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | We would like to show you a description here but the site wont allow us. However, the timer does not work anymore. The cord does feel warm to the touch. I have 2 extension cords running to plug it in. the problem lies, where the power dies. Or, a loose pipe coming into the pump can allow air intake. Check it out, it could start a fire! Air can also enter through split vac hoses, but since yours is new Third problem could be if the new pump moves much more water than the old pump (not all horsepower pumps are the same 2 different pumps of the same hp, can produce vastly different flow rates. To fix the problem, manually reset the Inspect Cell LED. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. The early revisions dont work with the TCELL5 or TCELL9. Hi Jim, sounds like an air leak, or low water in the pool, or a stuck skimmer weir blocking water flow into the skimmer. Hi Stephen, your spa waterfall, is that a spillover or an actual waterfall feature? Lighting, Learn About Pump Surging also occurs from low water level, or air leaks in front of the pump. 1. They are cheap and easy to replace. I have a Hayward 1.65 variable speed pump it is on a timer for high and low. We are getting a reading o the remote stating chlorinator is turned off High Temperature. Theres not much room back there for wires, and if they get too close to other things. it continues to cycle this way. and loosing its prime . Everything coming in appears to be tight. Hi David, an air leak will always come from a point BEFORE the impeller. I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. My pump just quit working, figured it was old so I replaced the motor. Inspect the centrifugal switch on the end of the shaft and the stationary switch mounted at 6 oclock and contacting the central centrifugal switch make sure all are intact and tightly secured, and not bent, broken or affected by mud or insects. Or very high mineral content (very hard water), or oily substances. Juat replaced motor. It is a Hayward Super Pump 1.5 HP (model #SP2610X15). Upon restart, pump sounds horrible, like pumping rocks. Look closely for any visible damage in the rear of the motor, anything loose, disconnected, chewed, melted, broken, burnt or cracked. Replaced breaker still nothing. If all is well then 99% sure it would be the capacitor, weak and needs replacement. Hi Shaun, if its not an air leak (from a loose pipe going into the pump, or loose pump lid, or low water level, or stuck skimmer weir), it then most likely is a clogged pump impeller. I needed to rotate the housing pump but for some reason the screws dont seem to b lined up. The article says: But higher pressure and no suction, that means an obstruction PAST the impeller. Put everything back in place, turned pool on. The Inspect Cell indicator will now reset and will later come back on after another 500 hours of use. Hi Heidi, it sounds like maybe the plumbing could be reversed? Even with the cells reverse polarity feature, the scale will still form on the plates. If still stumped, use a power meter to find the problem lies where the power dies, and trace power from the breaker to the timer or outlet, to the motor. I have a new pump and brand new grid inside my filter i have no leaks after about 10 minutes my jets stop i back wash filter and it works for about 10 min again i am stumped. Ive checked all my hoses for clogs and skimmer and pump baskets are clean. Hi Bill, when it goes into spa mode, the spa drain valve should open, and close off the pool suction valves, so that all the water is coming into the pump from the spa only. They disappear when the pump is at a high speed. From the Hayward Ecostar Owners Manual: the Heat Sink Overheated error indicates that the heatsink on the bottom of the drive has overheated. The usual spot is the pipe that threads into the pump did you use Teflon tape and/or silicone sealant on the threads? "caption": "In The Swim Blog"
If needed, you could replace just the motor, and the shaft seal, and save a few hundred bucks. If it is not, re-align your flow switch. This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. Whats the best and safest way to troubleshoot? I purchased a hayward powerflo matrix 1.5 pump and Proseries 21 Filter a week and a half ago. Check the wiring on the hi/lo switch, and follow it closely (trace it) to be sure all ends are connected, not corroded, or covered in insects or debris. Another check to do is to place the multiport valve on recirculate, which bypasses the filter, and will let you know for sure that the problem is in the filter sand. Automatic restart 2 minutes after error is corrected. We are trying to figure a way to start pumping the water put to clean the pool and get it going but we cant work the pump. If you have a local electric motor shop in town, you could drive your motor over there for testing. Usually get 3-4x that long. Joe, must be a bad motor yeah, to pull 58 amps, never heard of such a thing! "image": {
Check the motor diagram for the voltage wiring diagram. I bought a new pump thinking was something wrong with pump on off switch. Check the shaft for free spinning movement, and check the capacitor for signs of failure (bulges, cracks, smoke). Wouldnt turn back on for a while even after manually flipping the switch. If the wires are tight, I would suspect a bad capacitor, or wiring to or from the capacitor. It is so poorly designed and the helper handle is basically useless because it bumps into the outlet flow tube and the jandy. },
Check the pump lid o-ring or gasket, and be sure the lid is very tight. Otherwise, it can be loose or corroded connections on the 3 wires that connect the motor to the drive. If the amps show a reading that isnt within range, then you should replace your Turbo Cell. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. What seems to be the problem. Pump lids are often easier to remove when the Filter Air Bleeder is opened, to relieve vacuum pressure. Hi, make sure that the switches are not loose, the centrifugal switch on the end of the shaft and the Stationary switch at 6 oclock. Now when it is turned on it works for a few seconds then stops pumping and makes a humming sound. "@type": "Person",
We are a registered 501(c)3 non-profit that is funded by user donations. Most likely, and unfortunately yes. BUT THE BEARINGS. I filled the pool to the level line, but the air bubbles stayed. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? Hi Lou, I call that surging, and when a pump does that, and the water level (in the pool) is good, and a stuck skimmer weir is not causing the problem, I would check for an air leak in front of the pump a small void before the impeller that is pulling air in. The small filter, usually at the wall? "identifier": ""
Seems like filter is dirty , so I bumped it several times (once with motor on to really force water through) that usually does it. If the shaft does spin fine, and is not locked up, you can try a new capacitor, or check your current cap, with an ohmmeter. Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. Work through the chart below if your heater displays the following error codes. My Hayward pump II LX 1.5 horsepower. There must be a leak. This is common maintenance for any pool Troubleshooting Your Hayward Aqua Rite System, Copyright 2020 INYOpools All rights reserved. That is usually the capacitor, a black cylinder in the back of the motor. Quite a criticism for something costing 33bn-plus. Hi Tom, there is an o-ring that seals up the tank flange to the valve flange, its usually on the valve, when you remove the valve, might need replacement and/or a good cleaning and lubing. If the filter pressure goes higher when this happens, it could be an obstruction inside the filter or filter valve, or after the filter on the return line. What do you suggest? I changed the GFI Breaker in the main panel, problem still the same. Hi Don, we call that surging and it is usually caused by an air leak on the suction side, which is usually on the pump lid o-ring, or a loose threaded fitting, coming into the pump, or sometimes a leaky skimmer or main drain valve but the problem is always before the impeller You can use shaving cream around the pump lid, pipe and valves, turn on the pump, and see where it gets sucked in, or sometimes the problem is evident without such a messy test. Check all the power wires for tight fit and no corrosion. http://www.inyopools.com/blogSHOP at our online store! The most common cause for this is turning the valve with the pump on, or not pushing the valve handle down fully as the valve is re-positioned. If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. Water level is good, pipe connections are sealed and I checked I rings which seem fineI cant seem to figure out what is wrong. The pump has been fine since installed, we started up he pool about 30 days ago no issues. Replace the seal in the same orientation as you removed it, and reassemble. All Products, View The pump/motor, is a power flow LX, 1.5 HP, model SP151521BC, & the Sand Filter is the pro series model S210T. The actual unit of measurement for DE powder (lol) is a 1 lb coffee can size scoop. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. We are a registered 501(c)3 non-profit that is funded by user donations.